Firefighting Payload

Huanxin UAV offers a comprehensive Firefighting Payload range for high-rise firefighting, forest fire control, emergency rescue, and complex aerial operations. The product lineup includes fire nozzles, fire hoses, fire buckets, dry powder extinguishing tanks, fire bomb launchers, fire bombs, release systems, dry powder fire balls, water-based fire bombs, and forest fire extinguishing bombs.

Designed for industrial UAV platforms, each Firefighting Payload features modular construction, flexible integration, and reliable mission performance. These solutions support aerial spraying, fixed-point release, payload dropping, and window-breaking fire suppression, helping improve operational efficiency and reduce risks in dangerous or inaccessible areas.

With strong adaptability across multiple scenarios, Huanxin UAV Firefighting Payload solutions are ideal for urban firefighting, forest protection, emergency response, and critical infrastructure safety missions.

Fire Nozzle Specification Table
Model Water Hose Length Material Nozzle Length Spray Distance Water Surface Diameter Nozzle Lift Adjustment
Fire Nozzle
Fire Nozzle
50–100 m (customizable) Carbon Fiber 3 m ≥20 m 25 mm / 40 mm Air-assisted lift / Descent prevention function (upgraded version)
Fire Hose Specification Table
Product Extinguishing Agent Type Installation Method Hose Diameter Spray Distance Operating Height Hose Length
Fire Hose
Fire Hose
Firefighting Foam / Firefighting Water Agent Quick-Release Structure 25 mm / 40 mm ≥20 m ≥80 m 100 m (customizable)
Aerial Firefighting Bucket Specification Table
Product Capacity Dimensions Net Weight Discharge Time Operating Voltage Control Method
Aerial Firefighting Bucket
Aerial Firefighting Bucket
≥30 L 500 × 500 × 300 mm 3.6 kg ≤4 s 5 V PWM
Dry Powder Fire Extinguishing Tank Specification Table
Product Spray Distance Tank Pressure Power Supply Voltage Extinguishing Agent Fire Suppression Coverage Tank Capacity
Dry Powder Fire Extinguishing Tank (10L / 20L / 30L)
Dry Powder Fire Extinguishing Tank (10L / 20L / 30L)
≥10 m 0.8–1.2 MPa 24 V Superfine Dry Powder 50 m³ / 100 m³ / 150 m³ 10 L / 20 L / 30 L
Window-Breaking Fire Bomb Launcher Specification Table
Product Main Body Material Window-Breaking Capability Maximum Range Electric Start Parameter Launch Capacity
Window-Breaking Fire Bomb Launcher
Window-Breaking Fire Bomb Launcher
Aluminum Alloy + Tempered Glass Directly breaks single 18 mm double-layer vacuum tempered glass (door thickness 16 mm) ≤50 m DC 12V 700HA 2 rounds / 4 rounds / 6 rounds
Window-Breaking Fire Bomb Specification Table
Product Overall Length Overall Weight Extinguishing Agent Type Dry Powder Net Weight Single-Round Fire Suppression Capacity
Window-Breaking Fire Bomb
Window-Breaking Fire Bomb
≤995 mm ≤3010 g ABC Superfine Dry Powder 1100 g 9.2 m³
6-Position Drop Release Specification Table
Product Material Dimensions Weight Power Supply Voltage Hook Spacing Control Signal Single Hook Payload Capacity Standard Hook Quantity
6-Position Drop Release
6-Position Drop Release
6061 Aluminum Alloy, Carbon Fiber, Stainless Steel 322 × 180 × 100 mm 1.42 kg 5 V 150 mm PWM, SBUS 30 kg 6
Dry Powder Fire Extinguishing Ball Specification Table
Product Ball Diameter Net Weight Deployment Method Alarm Loudness Effective Fire Suppression Space Automatic Activation Time Extinguishing Agent Type Installation Method
Dry Powder Fire Extinguishing Ball
Dry Powder Fire Extinguishing Ball
215 mm 4 kg Sequential Electronic Control 240 dB 9 m³ ≤3 s ABC Superfine Dry Powder Hook Mounting
Dry Powder & Water-Based Fire Extinguishing Bomb Specification Table
Product Bomb Length Bomb Diameter Deployment Method Operating Method Operating Temperature Service Life Safety Distance Delay Accuracy Control Method Spray Radius Coverage Area Drop Height Extinguishing Agent Type Filling Capacity
Dry Powder & Water-Based Fire Extinguishing Bomb (15L / 25L / 50L)
Dry Powder & Water-Based Fire Extinguishing Bomb (15L / 25L / 50L)
375 mm / 390 mm / 450 mm Φ300 mm / Φ390 mm / Φ440 mm Vertical Precision Drop Mid-Air Activation and Spray -20°C to 55°C 2 Years ≥3 m ≤5 ms Fixed-Height Activation ≥5 m / ≥5 m / ≥10 m ≥30 m² / ≥70 m² / ≥100 m² 2 s fixed height 30 m, 3 s fixed height 60 m ABC Superfine Dry Powder; Water-Based Gel Fire Extinguishing Agent ABC superfine dry powder version: nominal filling 10 kg / 25 kg / 35 kg
Water-based agent version: nominal filling 13 kg / 25 kg / 50 kg
Forest Fire Extinguishing Bomb Specification Table
Product Bomb Length Bomb Diameter Deployment Method Operating Method Operating Temperature Service Life Response Time False Trigger Protection Custom Parameter Setting Safety Configuration Spray Radius Coverage Area Drop Height Applicable Fire Types Filling Capacity
Forest Fire Extinguishing Bomb (15L / 25L / 50L)
Forest Fire Extinguishing Bomb (15L / 25L / 50L)
560 mm / 690 mm / 865 mm Φ226 mm / Φ285 mm / Φ349 mm Precision Drop High-Altitude Aerial Burst and Spray -20°C to 60°C 3 Years ≤0.5 s Triple Protection Parameters can be configured according to actual fire conditions Multiple safety protections with both software and hardware Dry powder: 6 m / 12 m / 20 m; Water-based: 3 m / 6 m / 10 m 15–30 m² / 50–80 m² / 100–200 m² 2 s fixed height 30 m, 3 s fixed height 60 m Dry powder: Class A, B, C, E fires; Water-based: Class A, B fires 15 L / 25 L / 50 L